What does pulse oximetry measure?
Show answerFunctional oxygen saturation of hemoglobin in arterial blood (SpO2)
What is the normal SpO2 range on room air?
Show answer95-100%
What physical principle allows a pulse oximeter to calculate SpO2?
Show answerDifferential absorption of light at two wavelengths by oxygenated vs deoxygenated hemoglobin
What two light wavelengths does a standard pulse oximeter probe use?
Show answerRed (about 660 nm) and infrared (about 940 nm)
Pulse oximetry's light absorption calculation is based on which law?
Show answerThe Beer-Lambert law
How can dark nail polish affect a pulse oximeter reading?
Show answerIt can cause a falsely low SpO2 reading
How does carbon monoxide poisoning affect a pulse oximeter reading?
Show answerIt causes a falsely elevated SpO2 reading, because carboxyhemoglobin is misread as oxyhemoglobin
How does methemoglobinemia affect a pulse oximeter reading?
Show answerSpO2 trends toward approximately 85% regardless of the patient's true oxygen saturation
How does patient motion typically affect a pulse oximeter reading?
Show answerIt causes artifact and an unreliable or inaccurate reading
How does poor peripheral perfusion affect the pulse oximeter signal?
Show answerIt produces a weak, absent, or dampened waveform and unreliable reading
In ____, the displayed SpO2 value lags slightly behind the patient's actual real-time oxygenation change.
Show answerpulse oximetry
Why should a pulse oximeter probe site be rotated periodically?
Show answerTo prevent pressure injury or skin necrosis at the site
What does capnography measure?
Show answerThe concentration of carbon dioxide in exhaled breath
What is the difference between a capnometer and a capnograph?
Show answerA capnometer gives only a numeric CO2 value; a capnograph also displays the CO2 waveform
What is the normal end-tidal CO2 (EtCO2) range?
Show answer35-45 mmHg