Plumbing Licensing: Fixture Installation and Venting

Fixture clearance, connection, and venting requirements for common plumbing fixtures tested on licensing exams.

30 cards · basic cards · AI-written, checked twice. Edit anything.

Study this set free Look inside first Get FlashKeepers for iPhone
Minimum clearance in front of a toilet for proper access
18 inches from the center line to any wall or fixture
Minimum bathroom width when a toilet is present
30 inches
Minimum side clearance on each side of a toilet
At least 15 inches from toilet center line to any wall
Minimum clearance in front of a pedestal sink
18 inches
Minimum counter depth clearance in front of kitchen sink
24 inches
Minimum side clearance for each side of a bathtub
At least 12 inches on each side
Minimum clearance required in front of a shower stall
24 inches
Minimum trap seal depth required by code
2 inches
Maximum trap seal depth allowed
4 inches
Required slope for drain lines and trap arms
1/4 inch per foot of horizontal run
Maximum slope allowed for horizontal drain lines
1/2 inch per foot
Maximum distance from fixture trap to vent opening
8 feet measured along the trap arm
Minimum height vent pipe must extend above roof
12 inches
Minimum distance from vent terminal to windows, doors, or air intakes
10 feet horizontal distance and 3 feet above the opening
Type of fitting required when connecting fixture drains to main stack
Sanitary tee or wye fitting; never 90-degree elbow