What is a Reduced Pressure Zone (RPZ) device?
A backflow prevention device with two check valves and a relief valve that maintains a pressure zone between them to prevent backflow in both directions.
What type of hazard requires an RPZ device instead of a Double Check Valve?
High hazard (health threat), such as chemical injection or contaminated water connections.
Define a cross-connection in plumbing.
A physical link allowing potable water to come into contact with non-potable or contaminated water.
What is backflow?
Reverse flow of non-potable water, contaminants, or wastewater into the potable water supply.
How does siphonage backflow occur?
When pressure in the potable water line drops below pressure in the cross-connected line, causing reverse flow.
How does pressure backflow occur?
When pressure from a cross-connected system exceeds the pressure in the potable water supply, forcing water backward.
What is a Double Check Valve Assembly used for?
Prevention of backflow in low-hazard cross-connections where the contaminant poses no health risk.
Where is an Atmospheric Vacuum Breaker typically installed?
On outdoor hose bibbs and indoor faucets to prevent siphonage of non-potable water.
At what minimum height must an Atmospheric Vacuum Breaker be installed above the outlet?
At least 6 inches above the flood level rim or highest opening of the outlet.
What is a Pressure Vacuum Breaker commonly used for?
Protection against backflow on lawn irrigation systems, heating systems, and low-hazard applications.
How does an Atmospheric Vacuum Breaker prevent backflow?
By allowing air to enter the line when pressure drops, which breaks the siphon and prevents reverse flow.
How often must an RPZ device be tested and certified?
Annually, by a certified backflow device tester.
How often must a Double Check Valve Assembly be tested?
Every five years by a certified backflow device tester.
What backflow device is required for a lawn irrigation system with chemical injection?
A Reduced Pressure Zone device, due to the high hazard of pesticide and fertilizer contamination.
What backflow device is required where a boiler system has its own water supply line?
A Reduced Pressure Zone device or Double Check Valve, depending on whether additives or high-temperature water poses a health hazard.