HVAC Load Calculation, Airflow and Psychrometrics

Manual J basics, CFM and duct design, psychrometric chart terms, humidity and comfort.

About this set

41 mixed cards for HVAC Certification HVAC/EPA 608. It opens with "What is Manual J load calculation used for?" and "Name three major components of a Manual J cooling load calculation". Study it alongside the other HVAC Certification sets below.

41 cards · mixed cards · AI-written, checked twice. Edit anything.

Study this set free Look inside first Get FlashKeepers for iPhone

Opens in your browser, no account. Get the iPhone and iPad app · Android app

What is Manual J load calculation used for?
Show answerTo determine the heating and cooling capacity required for a building based on its structure and climate.
Name three major components of a Manual J cooling load calculation.
Show answerExternal loads (solar gain, outdoor air), transmission losses through walls and roof, internal gains (people, equipment).
What does CFM stand for?
Show answerCubic feet per minute, a measure of volumetric airflow rate.
What is ACH in HVAC?
Show answerAir Changes Per Hour, the number of times total air volume in a space is replaced per hour.
Define static pressure in a duct system.
Show answerThe perpendicular force air exerts on duct walls, measured in inches of water column (IWC).
What is a psychrometric chart primarily used for?
Show answerTo determine relationships between dry bulb temperature, humidity, enthalpy, and other air properties.
On a psychrometric chart, what does dry bulb temperature represent?
Show answerThe actual air temperature measured with a standard thermometer, plotted on the horizontal axis.
What is wet bulb temperature?
Show answerThe lowest temperature air can reach through evaporative cooling, measured with a wet cloth around the thermometer bulb.
Define relative humidity (RH).
Show answerThe ratio of actual water vapor pressure to saturation pressure at the same temperature, expressed as a percentage.
What is dew point?
Show answerThe temperature at which air becomes saturated and water vapor begins to condense into liquid.
Define enthalpy in psychrometrics.
Show answerThe total heat energy in air, including sensible heat and latent heat of water vapor, measured in BTU per pound of dry air.
What is sensible heat?
Show answerHeat that increases or decreases air temperature without changing its moisture content.
What is latent heat load in HVAC?
Show answerHeat required to evaporate or condense moisture without changing air temperature, typically from occupants and ventilation air.
What is the typical comfortable indoor relative humidity range?
Show answer30 to 60 percent, with optimal comfort around 40 to 50 percent.
What is the typical comfortable indoor temperature range according to ASHRAE 55?
Show answer68 to 76 degrees Fahrenheit (20 to 24 degrees Celsius) in winter, 72 to 80 degrees Fahrenheit (22 to 27 degrees Celsius) in summer.