Manual J basics, CFM and duct design, psychrometric chart terms, humidity and comfort.
41 cards · mixed cards · AI-written, checked twice. Edit anything.
- What is Manual J load calculation used for?
Show answer
To determine the heating and cooling capacity required for a building based on its structure and climate.
- Name three major components of a Manual J cooling load calculation.
Show answer
External loads (solar gain, outdoor air), transmission losses through walls and roof, internal gains (people, equipment).
- What does CFM stand for?
Show answer
Cubic feet per minute, a measure of volumetric airflow rate.
- What is ACH in HVAC?
Show answer
Air Changes Per Hour, the number of times total air volume in a space is replaced per hour.
- Define static pressure in a duct system.
Show answer
The perpendicular force air exerts on duct walls, measured in inches of water column (IWC).
- What is a psychrometric chart primarily used for?
Show answer
To determine relationships between dry bulb temperature, humidity, enthalpy, and other air properties.
- On a psychrometric chart, what does dry bulb temperature represent?
Show answer
The actual air temperature measured with a standard thermometer, plotted on the horizontal axis.
- What is wet bulb temperature?
Show answer
The lowest temperature air can reach through evaporative cooling, measured with a wet cloth around the thermometer bulb.
- Define relative humidity (RH).
Show answer
The ratio of actual water vapor pressure to saturation pressure at the same temperature, expressed as a percentage.
- What is dew point?
Show answer
The temperature at which air becomes saturated and water vapor begins to condense into liquid.
- Define enthalpy in psychrometrics.
Show answer
The total heat energy in air, including sensible heat and latent heat of water vapor, measured in BTU per pound of dry air.
- What is sensible heat?
Show answer
Heat that increases or decreases air temperature without changing its moisture content.
- What is latent heat load in HVAC?
Show answer
Heat required to evaporate or condense moisture without changing air temperature, typically from occupants and ventilation air.
- What is the typical comfortable indoor relative humidity range?
Show answer
30 to 60 percent, with optimal comfort around 40 to 50 percent.
- What is the typical comfortable indoor temperature range according to ASHRAE 55?
Show answer
68 to 76 degrees Fahrenheit (20 to 24 degrees Celsius) in winter, 72 to 80 degrees Fahrenheit (22 to 27 degrees Celsius) in summer.