What is a Class I hazardous location?
An area where flammable gases, vapors, or mists that can form explosive atmospheres are or may be present.
What is a Class II hazardous location?
An area where combustible dust is or may be present in sufficient quantity to create an explosion hazard.
What is a Class III hazardous location?
An area where easily ignitable fibers or flyings are present but not suspended in sufficient quantity to create an explosion hazard.
In Class I Division 1, when is the explosive atmosphere present?
Under normal operating conditions.
In Class I Division 2, when is the explosive atmosphere present?
Only during abnormal operating conditions or as a result of infrequent maintenance.
In Class II Division 1, when is combustible dust present?
During normal operations or as a result of routine processing.
In Class II Division 2, when is combustible dust present?
Only during abnormal conditions or as a result of infrequent maintenance.
In Class III Division 1, what condition exists?
Easily ignitable fibers or flyings are actively handled, manufactured, or stored.
In Class III Division 2, what condition exists?
Easily ignitable fibers or flyings are stored but not being handled or manufactured.
What is Zone 0?
An area where an explosive atmosphere is present continuously, or for long periods, or frequently.
What is Zone 1?
An area where an explosive atmosphere is likely to occur in normal operation, or frequently present.
What is Zone 2?
An area where an explosive atmosphere is unlikely in normal operation and, if it occurs, only infrequently and for short periods.
What primary protection method must equipment use in Class I hazardous locations?
Explosionproof construction or intrinsically safe design to contain any internal explosion.
What primary protection method must equipment use in Class II hazardous locations?
Dust-tight construction to prevent dust infiltration and minimize dust collection on internal surfaces.
What protection is required for equipment in Class III hazardous locations?
Dust-tight construction to minimize fiber collection on internal surfaces and prevent ignition of accumulated fibers.